WattSpec Logo WattSpec

Check off the critical devices you want to keep running during an electrical grid failure to calculate peak inrush surge and continuous load.

⚡

Whole-House Generator Sizer

Presets:
Selected Outage Appliances
Required Electrical Capacity
Continuous Running 0W
Peak Inrush Surge 0W
Load Tier Awaiting Selection
Recommended Generator: 0 kW
⛽ Outage Duration & Fuel Reserve Planner
⛽ Est. Gasoline Needed: 0 Gal
🔵 Or 20 lb Propane Tanks: 0 Tanks

*Tip: Store fuel with stabilizer (STA-BIL) to prevent gumming, and keep 5-gallon EPA cans ready.

Matched Power Equipment
Select appliances above to calculate sizing and live equipment matches.
🛡️ Generator Safety (25-Foot Rule): Always operate generators at least 20 to 25 feet away from windows and doors to prevent carbon monoxide poisoning. For 25–50 ft distances, use an all-weather 10 AWG extension cord.

How the WattSpec Generator Sizing Formula Works

Electricians calculate backup generator capacity using three core principles:

  1. Total Running Load: The continuous wattage of all devices operating simultaneously.
  2. Largest Motor Startup Surge: Motors do not start at the same millisecond. Peak surge is calculated as the sum of all running watts plus the surge difference of the single largest motor.
  3. 20% Continuous Safety Margin: Generators should not run at 100% maximum capacity continuously. Adding a 20% cushion prevents overheating.